    《Mantunsci S3 Series Rental Housing Smart Safety Distribution and Metering Management System Schemes》

    Views:3    Time:2019-05-20

    1.    Rental Housing Smart Safety Distribution and Metering Management System Scheme

     

    1. Summary of the scheme

    This scheme adopts the intelligent power management system and the Mantunsci S3 series of smart miniature circuit breakers, which are used as safety protection and measurement for each household in the rental house. It can be installed directly on the rails of low-voltage power distribution cabinets in the floor distribution room.

    The sub-rental can be installed in a lighting box in the living room or hallway.

     

    2. System configuration and product selection

    In the low-voltage distribution room on the floor, each rental house can be equipped with a wisdom micro-break with leakage protection and Mantunsci S3-ZNC63, 220VAC, 63A, 2P (each switch actually takes 3P position on the electrical box rail).

    Each 8 room in the distribution room is equipped with a S3-P25 power module (each occupying 2P position, plus one for each additional 8);

    One S3-T30 communication module is equipped per power distribution room (1P location, plus one if more than 24 rooms and add a network cable).

    Number

    Name

    Model

    Quantity

    Annex

    01

    Single-phase, 2P, smart micro-break with leakage protection

    S3-ZNC63

    N=Number of households

    Self-inspection with leakage protection function.

    Rated current:63A

    Breaking capacity:6KA

    02

    Power supply and surge protection module

    S3-P25

    1

    DC12V\2.5A

    03

    Communication module

    S3-T30

    1

    TCP protocol with network port

     

     

    ◎ Installation requirements:

    1. When designing, you should leave the RJ45 network cable connector or socket in the low-voltage power distribution cabinet of the power distribution room, which is located near the installation position of the communication module T30. If the environment is not convenient for wiring, you can also choose the wireless WIFI working mode as long as the full coverage of WIFI signal;

    2. When designing, it is recommended to leave more 1P space for the low-voltage distribution cabinet rail to facilitate the installation of intelligent micro-break and related accessories.

    3. It can remotely control the use of electrical appliances, overload protection, short circuit protection, leakage protection, and meter power consumption.

     

     

    2. Indoor Subleasing Smart Safety Distribution and Metering    System Scheme

    1. Summary of the scheme

    This scheme adopts the intelligent power management system and the Mantunsci S3 series of smart miniature circuit breakers, which are used as safety protection and measurement for each household in the rental house. It can be installed directly on the rails of low-voltage power distribution cabinets in the floor distribution room.

    The sub-rental can be installed in a lighting box in the living room or hallway.

    2. System configuration and product selection

    In indoor lighting box or corridor, each rental house can be equipped with a wisdom micro-break with leakage protection and Mantunsci S3-ZNC63, 220VAC, 63A, 2P (each switch actually takes 3P position on the electrical box rail).

    Each large suite is equipped with one S3-P25 power module (each occupying 2P position) and one S3-T30 communication module (occupying 1P position).

    Number

    Name

    Model

    Quantity

    Annex

    01

    Single-phase, 2P,   smart micro-break with leakage protection

    S3-ZNC32

    N=Number of   subleased rooms

    Self-inspection   with leakage protection function.

    Rated current:63A

    Breaking   capacity:6KA

    02

    Power supply   and surge protection module

    S3-P25

    1

    DC12V\2.5A

    03

    Communication   module

    S3-T30

    1

    TCP protocol with network port

     

     

    ◎ Installation requirements:

    1. When designing, you should leave the RJ45 network cable connector or socket in the lighting power box, which is located near the installation position of the communication module T30. If the environment is not convenient for wiring, you can also choose the wireless WIFI working mode as long as the full coverage of WIFI signal;

    2. When designing, it is recommended to leave more 1P space for the low-voltage distribution cabinet rail to facilitate the installation of intelligent micro-break and related accessories.

    3. It can remotely control the use of electrical appliances, overload protection, short circuit protection, leakage protection, and remotely measure the electricity consumption of each sub-rental room.