▓万和彩票平台官网▓赔率最高,提款速度最快。万和彩票平台专注彩票经营10余年,信誉口碑业界驰名;在我们万和彩票平台聊天室玩家每天可领取现金红包!我们[万和彩票平台]将给您提供一个安全/稳定/秒速的彩票平台!...

  • Solutions

    《Mantunsci S3 Series Smart Safety Distribution and Metering Management System Scheme in Dormitory》

    Views:3    Time:2019-05-20

    1. Summary of the scheme

    This scheme adopts the intelligent power management system and the Mantunsci S3 series of smart miniature circuit breakers, which are used as safety protection and measurement for each dormitory. It can be installed directly on the rails of low-voltage power distribution cabinets in the floor distribution room, or in the lighting electrical boxes in the dormitory.

     

    2. System configuration and product selection

    a. In the low-voltage distribution room on the floor, each rental house can be equipped with a wisdom micro-break with leakage protection and Mantunsci S3-ZNC63, 220VAC, 32A, 2P (each switch actually takes 3P position on the electrical box rail);

    Each 8 room in the distribution room is equipped with a S3-P25 power module (each occupying 2P position, plus one for each additional 8);

    One S3-T30 communication module is equipped per power distribution room (1P location, plus one if more than 24 rooms and add a network cable).

    Number

    Name

    Model

    Quantity

    Annex

    01

    Single-phase, 2P, smart micro-break with leakage protection

    S3-ZNC32

    N=Number of dormitories

    Self-inspection with leakage protection function.

    Rated current:32A

    Breaking capacity:6KA

    02

    Power supply and surge protection module

    S3-P25

    1

    Plus 1 for every 8 rooms

    03

    Communication module

    S3-T30

    1

    Plus 1 for every 24 rooms

     

    b. Install a smart micro-break with leakage protection and Mantunsci S3-ZNC32, 220VAC, 32A, 2P in each dormitory. (Each switch actually takes 3P position on the electrical box rail) and configure an S3-P25 power module and a S3-T30 communication module.

    Number

    Name

    Model

    Quantity

    Annex

    01

    Single-phase, 2P, smart micro-break with leakage protection

    S3-ZNC32

    1

    Self-inspection with leakage protection function.

    Rated current:32A

    Breaking capacity:6KA

    02

    Power supply and surge protection module

    S3-P25

    1

    DC12V\2.5A

    03

    Communication module

    S3-T30

    1

    TCP protocol with network port

     

    Installation requirements:

    1. When designing, you should leave the RJ45 network cable connector or socket in the low-voltage power distribution cabinet of the power distribution room, which is located near the installation position of the communication module T30. If the environment is not convenient for wiring, you can also choose the wireless WIFI working mode as long as the full coverage of WIFI signal;

    2. When designing, it is recommended to leave more 1P space for the low-voltage distribution cabinet rail to facilitate the installation of intelligent micro-break and related accessories;

    3. It can remotely control the use of electrical appliances, overload protection, short circuit protection, leakage protection, and meter power consumption.

     


    Previous:《Mantunsci S3 Series Smart Safety Distribution and Metering Management System Scheme in Hotel Apartment》 Next:《Mantunsci S3 Series Rental Housing Smart Safety Distribution and Metering Management System Schemes》

    Return
    万和彩票平台 万和彩票注册链接 万和彩票手机app 万和彩票网址导航 万和彩票平台官网 万和彩票平台注册 万和彩票网址导航 万和彩票手机版 万和彩票最新网址 万和彩票平台注册 万和彩票官网入口